Waterproof switch Metal Indicator Light Plastic Indicator Lamp LED Holder series Plastic push button ... Rocker switch&Panel USB socket& charger Toggle switch Micro switch Auto Switch Proximity Switch Overload circuit breaker AC socket Clip & Plug & Jack More electronics Terminal & Connector Cooling Fan Inverter Transformer HV Power Transmission

Tel:+86-577-61776977
      Mobi:+86-18066330701
Wechat:abbeycon18066330701
Skype:abbeycon827@outlook.com
Email:power@cnvcb.com

J1 series of auto voltage reducing starting control cabinet
Model
J-----------------------------------------voltage reducing starting
1-----------------------------------------design No.
□----------------------------------------transfer method: B: closed circuit transfer
                                          K: open circuit transfer
□----------------------------------------voltage (V)
□---------------------------------------- working code
                                       1: the first working combination
                                       2: the second working combination
Note:  the first working combination: 8 hours working time; uninterrupted working system; short-time working system; 3 times each hour during intermittent periodic duty , and 6 times each hour during the aperiodic operation, and then the temperature should be the same as that of the ambient.
      The second working combination: 8 hours working time; uninterrupted working system; short-time working system; 3 times each hour during intermittent periodic duty , and 12times each hour during the aperiodic operation, and then the temperature should be the same as that of the ambient.
 
 Technical parameter

 
1) the main technical parameters see table 1
2) the starting performance
a. 2 times of uninterrupted starting, starting time 15s, interval time 30s
b. one time or several times of uninterrupted starting., the total starting time see table 1. the temperature of the autotransformer should be the same or lower than the ambient temperature when restart
3) current transfer realize the transfer from starting to operation: when the starting current is 1.5 times lower than the rated working current, 4) the protection of the autotransformer is by forced transfer of the current-time equipment.
 

Serial No.
Specification
Working current reference value (A)
Current transfer reference value (A)
Thermal relay current reference value (A)
MAX total starting time (S)
Automatic switch electromagnetic trip rated current (A)
1
J1B-11/380-1
22
3.3
22
30
32
2
J1B-15/380-1
29
4.4
29
30
40
3
J1B-18/380-1
36
5.3
36
40
40
4
J1B-22/380-1
42
4.2
42
40
40
5
J1B-30/380-1
57
5.7
57
40
63
6
J1B-37/380-1
70
5.3
70
60
80
7
J1B-45/380-1
84
6.3
84
60
100
8
J1B-55/380-1
103
3.8
103
90
125
9
J1B-75/380-1
140
5.2
140
90
180
10
J1B-100/380-2
184
4.6
3.0
90
200
11
J1B-115/380-2
219
5.4
3.7
90
250
12
J1B-135/380-2
252
3.1
2.1
90
315
13
J1B-190/380-2
351
4.3
2.9
90
400
14
J1B-225/380-2
407
3.8
2.5
90
500
15
J1B-260/380-2
469
4.4
2.9
90
530
16
J1B-300/380-2
537
5.0
3.4
90
630
17
J1K-100/380-2
184
4.6
3.0
90
200
18
J1K-115/380-2
219
5.4
3.87
90
250
19
J1K-135/380-2
252
3.1
2.1
90
315
20
J1K-190/380-2
351
4.3
2.9
90
400
21
J1K-225/380-2
407
3.8
2.5
90
500
22
J1K-260/380-2
469
4.4
2.9
90
500
23
J1K-300/380-2
537
5.0
3.4
90
600
 